UN/DOT Performance Test - Solids

UN/DOT Performance Test - Solids

UN/DOT Performance Test - Solids

49 CFR 178.601-178.609

UN/DOT certification for packaging that carries solid hazardous materials

UN/DOT certification for packaging that carries solid hazardous materials

Required before you can legally ship a regulated solid. The packaging is qualified as a design type, not per shipment, and the certification is what lets you apply the UN specification marking.

Required before you can legally ship a regulated solid. The packaging is qualified as a design type, not per shipment, and the certification is what lets you apply the UN specification marking.

SAMPLES NEEDED

6 complete units

LAB TIME

4 business days

TYPICAL TURNAROUND

1-7 days

RE-TESTING

Every 24 months

You probably need this if

You are bringing a new hazardous product to market and need the packaging certified

Your packaging design changed - a different board grade, closure or inner packaging

Your existing certification is at or near its re-test interval

A carrier or customer asked for the UN test report

What the test involves

The sequence we run for UN/DOT Performance Test - Solids. Exact parameters are confirmed against the current revision of the standard before testing begins.

01

Test plan and UN marking review

02

UN specification marking verification

03

Preconditioning at 23 C / 50% RH

Required for fiberboard per 49 CFR 178.602(d)

04

Drop test per packing group

Height set by packing group

05

Stacking test, 24-hour dead load

49 CFR 178.606

06

Vibration test

49 CFR 178.608

07

UN test report and certification package

What to send us

6 complete packaged samples, assembled exactly as they ship.

Design drawings or a packaging specification, if you have them.

The Safety Data Sheet — required before regulated testing can begin.

Ship to 9708 Industrial Drive, Bridgeview, Illinois 60455.

Not sure the count is right for your configuration? We confirm it with you before you ship anything.

This certification expires

UN/DOT Performance Test - Solids is normally re-tested every 24 months, and sooner if the packaging changes. We keep track of when your testing comes due and tell you before it lapses — you should not find out from a rejected shipment.

Common questions

How is the drop height decided?

By packing group. Packing Group I drops from 1.8 m, Group II from 1.2 m, Group III from 0.8 m, per 49 CFR 178.603.

How many samples do you need?

Six complete packaged samples for a standard solids sequence, assembled exactly as they will ship. We confirm the exact count with you before you send anything.

Do I need to send the actual hazardous material?

Usually not. Testing is normally run with a surrogate of equivalent properties. Confirm the surrogate with the engineer before shipping, and send the SDS either way.

Not certain UN/DOT Performance Test - Solids is the right test?

Answer a few questions about what you ship and we will tell you which standard applies — and why the others do not.